Hey, I'm Brian from Easy Travel Vans and
today we're going to be talking about
how to dewinterize your coach. So,
springtime has come now and we want to
get the antifreeze fluid out of the
coach that was in there that we used to
winterize the coach back in fall. So,
there is a standard operating procedure
that we can also go according to. This
is something that we made that you can
use to help follow through when
dewinterizing your coach. This is
something that can also be found on our
website if you need to find it there or
you can contact our customer service
department for it. So, the first thing
that we're going to do is we're going to
grab the inlet filter for the water
heater. This is what's going to go
inside the water heater. First thing we
want to do as well is make sure that
there's two O-rings that are still in
place on this inlet filter. So, if these
are not in place or if they are cracked
or damaged in any way, they will need to
be replaced. So, just pay attention to
those two O-rings. If they're not in
place, you will get a leak on your water
heater when you do start to pressurize
the coach. So, we'll open up the water
heater door here.
This is going to be the flap that we
need to fold down. There's a little tab
right here that needs to be pushed up.
And then this will drop down. And this
is where that inlet filter is going to
go. So, we're just going to slide that
in place. And you can see once it's all
the way in, then this yellow tab right
here, that'll actually grab onto it and
it'll push it back up in place and lock
in place like that. Make sure that this
valve is closed still as well. This is a
pressure release valve. If it happens to
be open, just make sure that's closed as
well. So, we're also going to want to
make sure that the water heater is still
in the bypass mode, which means you're
going to want to have valves A, B, and E
closed, as well as D. In this case, you
can see that valve D is open. So, we're
going to close that. That's the drain
valve. So, we're going to close that.
These are closed. This is A, E, D, and B
is down here. They're closed. And C is
still open. C is your bypass valve. So,
that one's the one that's still mixing
the the hot and the cold together. So,
right now, this is the way that it's set
for the bypass mode. Okay. So, now that
we have the water heater inlet filter in
place and the water heater is set to
bypass mode, we're going to come over to
the utility center here and we're going
to hook up the city water connection.
So, we'll hook up the city water
connection. And as we're in this area as
well, we're also going to make sure that
the city water valve is set to city
water only, as this one is. And also the
winterized valve. We're going to change
that to make sure it's set to normal
flow. So, this is the way it's set to
normal flow. So, we're going to make
sure normal flow, city, and normal
water, and your city water connectors is
hooked up. Once you've done this, you
can turn the city water supply on, and
we'll go inside the coach, and we'll
start flushing out all of the water
lines. So, now that we're inside the
coach, we're going to go to each
individual faucet and we're going to
open them up and try to flush out all of
the pink fluid that's in there. And
you're going to see that it's going to
start off a little bit pink, but then
it'll turn clear pretty quick. You're
going to want to make sure you do that
both on the cold and on the hot. Make
sure that it all runs clear. We're going
to go to each faucet one at a time and
complete this. So, this is the one at
the galley. This one's running nice and
clear.
So, we'll turn that off and we'll go
over to the vanity. So here in the
vanity as well, we'll again open the
faucet up and you can see the pink fluid
come out.
Once that change is clear, we'll make
sure both sides are clear. Then we
should be good. Everything's running
clear. So again, we're going to want to
make sure we do this at every single
faucet. So that includes the shower. So
again, we'll get the the cold water
running. Make sure that's flushed out,
all the pink fluid is out of there.
Once that's running clear, we'll go over
to the hot and open up that one as well.
And again, make sure that all the pink
fluid is out of there. and it is running
nice and clear.
So, inside the coach here, we we've
already done the galley faucet. We've
done the vanity faucet, the toilet, and
the shower. But, we also want to do the
drain valve for the circulation line on
the Truma water heater. So, the drain
line is valve D right here. So, we're
going to open that one up for a couple
seconds. What this is going to do is
flush the fluid out in the drain line,
and it's going to be pouring out on the
bottom of the coach. You could have
somebody outside just keeping an eye on
that to make sure that it's running
clear. Or you can just let it run like
this for a couple seconds, maybe 5, 10
seconds, just to make sure that
everything is going to be nice and clear
running out of there. So again, it's
been running for a little while right
now. I feel confident that it will be
clear water out.
So we'll just turn that valve D back off
and then we're ready to go outside and
do the same thing on the exterior
shower.
Okay. So, next thing on the outside
faucet here, the outside shower faucet,
we're just going to stick this hose into
there.
And again, we're just going to hold that
in. And then as we hold that in, we'll
open this up.
You'll see some of the pink fluid come
out.
Again, anifreeze is running clear.
Do that with both sides.
There we go. Once that's running clear
again, then we should be good. We can
turn that off. Okay. So, at this point,
we've basically flushed all the water
lines free of the antifreeze, but there
is still a chance that there's some
water left in the water pump and the
line from the water pump to the rest of
the system. So, what we're going to do
is we're going to change this over to
tank fill only. So, when we change that
over, you'll hear that the water starts
running into the fresh tank. If by
chance you've left the drain valve open
on the fresh tank, we're going to close
that. So, we're going to let the water
run into the fresh tank. We're going to
fill the fresh tank just to make sure it
gets flushed out as well. But then once
the tank is full, you will again see
water pouring out underneath the coach
because there is an overflow hose on the
tank. So, once it is 100% full, that
tank will overflow and it'll flow out
onto the ground underneath the coach.
Once it does that, you know the tank is
100% full. You can turn this valve back
to normal and city water and you can
turn off the water city water connection
supply and also disconnect the city
water hose. So, we're going to come
inside the coach. We'll turn the water
pump on. That'll start drawing water
from the fresh tank. Once it does, we
can turn the faucets on again. We're
going to flush out any remaining
antifreeze that could be in there. So,
again, we're going to go to the cold and
to the hot. Just making sure that it's
still clear water that's coming out of
there. Once we do that at the galley
faucet, we're going to go back into the
bathroom area and we're going to do that
again on the vanity, the toilet, the
shower, and the exterior shower as well.
So, making sure we're doing every single
one of those water faucets and supplies
that we have. Making sure everything is
flushed out and clear. So, now that
everything has been flushed, clean, and
clear of all the plumbing antifreeze, we
can now reinstall the cartridge for the
water filter. Now, this is only
applicable to unities. The Wonders do
not have a built-in water filter. So,
we're going to do this on the Unity. So,
what we want to do is make sure that the
water pump is turned off. And once the
pump is turned off, we're just going to
open up a valve just to make sure
there's no pressure in the system
anymore. Cuz if you open up the canister
for the filter, you'll get a lot of
water pouring out if there is still
pressure. Once the pressure has been
released, we'll go ahead and remove the
canister from the filter and we can
insert the new cartridge.
Okay, so the next thing that we're going
to want to do is we're going to want to
set the water heater to normal flow. In
order to do that, we're going to open up
valves A, valve E, and valve B. We're
going to have those open, and we're
going to keep valve D, and valve C
closed.
So, that's how it's going to be set to
normal flow. So, at this point, your
coach should be dewinterized and ready
for use, and you should be ready to hit
the road.