So Ryan, regarding the the tank sensors,
is there anything else we need to be
aware of on that?
Yeah, so with the tank sensors, these
are ultrasonic sensors that are actually
physically inside the tank. So they are
looking for where the water and the air
meet in the tank. So if the tank is
completely empty or completely full, the
system can get confused because it can't
find the difference between the water
and the air. So with that, you may get
an empty reading. You might get a bit of
a 10% reading or it might just say NA at
the bottom.
So Ryan, if there's any errors with that
sensor, where could we where can we view
that if we need to call service?
So yeah, if you service asks you, you
can press and hold on the tank levels
here for about 5 seconds and let go. So
then it'll just show you your level in
percent. So here it's zero and it'll
show you an error if there is any. So in
this case we have no errors.
So how do we get back to the other
screen then?
You do the exact same thing. Just hold
press and hold for 5 seconds.
So Ryan, any other tips or tricks we in
regards to filling the tanks?
Yeah. So our suggestion is is that you
have the system on while filling the
tank. So that way the system will
actually watch. You'll be able to see
your tank levels rise here and it'll
reach full and then it will kind of
remember that it's full when you turn
the system off and back on or and the
same thing was when you're emptying
them. Make sure that you have the system
on so that it can watch you actually
empty them. Because if you say you have
it empty and you fill it up while the
system's on, but then you turn your
disconnect off and then fully drain it,
then the system because it can't find
that level, won't be able to actually
know if the tank is empty or full and it
might still think it's full because of
the last known position.
So, uh, Ryan, let's say let's say we do
have that error where we've turned the
power off in between dumping the tanks.
How will we reset that?
So, the easiest way to reset that is
just by either with the system on
emptying or filling the tanks just a
little bit. Often just like 5 gallons of
water will help fix it if it's actually
empty. Or you just drain it a little bit
so that you can actually see the line in
the tank.